News_042008 27-11-2009-Pain perception during esophageal warming due to radiofrequency catheter ablation in the left atrium.

 

 

J Interv Card Electrophysiol. 2009 Nov; [Epub ahead of print]
PMID: 19943098 [PubMed - as supplied by publisher]

 

 

Galeazzi M, Ficili S, Dottori S, Elian MA, Pasceri V, Venditti F, Russo M, Lavalle C, Pandozi A, Pandozi C, Santini M.


 

Dipartimento Cardiovascolare, Ospedale San Filippo Neri, Via Giovanni Martinotti 20, 00135, Rome, Italy, m.galeazzi@lycos.com

 

 

PURPOSE: We investigated the relationship among esophageal warming, pain perception, and the site of radiofrequency (RF) delivery in the left atrium (LA) during the course of catheter ablation of atrial fibrillation. Such a procedure in awake patients is often linked to the development of visceral pain and esophageal warming. As a consequence, potentially dangerous complications have been described. METHODS: Twenty patients undergoing RF ablation in the LA were studied. An esophageal probe (EP) capable of measuring endoesophageal temperature (ET) was positioned before starting the procedure. The relative position of the EP and the tip of the ablator were evaluated through fluoroscopy imaging before starting each RF delivery, during which the highest value of the temperature was collected. After RF withdrawal, the patients were asked to define the intensity of the experienced pain by using a score index ranging from 0 (no pain) to 4 (pain requiring immediate RF interruption). RESULTS: The mean ET value during ablation was 39.59 +/- 4.71 degrees C. The EP proximity to the ablator's tip showed a high correlation with the development of the highest ET values (Spearman's rank correlation coefficient r = 0.49, confidence interval (CI) 0.55-0.41). Moreover, the highest values of pain intensity were reported when the RF was delivered to the atrial zones close to the EP projection (r = 0.50, CI 0.55-0.42) and when the highest ET levels were reached (r = 0.38, CI 0.30-0.45). CONCLUSIONS: Pain perception in LA ablation is significantly related to esophageal warming and is higher when the RF is delivered near the esophagus. It seems advisable to perform ET monitoring in sedated patients to avoid short- and long-term jeopardizing of the esophageal wall.

 

 

Back
 

 

©Johnson & Johnson Medical NV/SA, 2010. Last update on:19 Mar 2012 This site is published by Johnson & Johnson Medical NV/SA, which is solely responsible for its contents. This section of the website is intended for visitors from the European Economic Area (EEA), excluding France. The EEA includes the 25 EU member states and Norway, Iceland, and Liechtenstein. Capitalized product names are trademarks of Biosense Webster.